宋超,刘钟阳,周博.臭氧发生设备监测与故障诊断的研究[J].电气自动化,2014,36(1):14~15
臭氧发生设备监测与故障诊断的研究
Monitoring and Fault Diagnosis of Ozone Generator
  
DOI:
中文关键词:  臭氧发生设备  功率监测  故障分析  故障特征  故障诊断
英文关键词:ozone generator  power monitoring  fault analysis  fault feature  fault diagnosis
基金项目:
作者单位
宋超,刘钟阳,周博  
摘要点击次数: 2723
全文下载次数: 0
中文摘要:
      臭氧发生器利用高频高压电源和介质阻挡放电产生臭氧,可能出现故障点较多,较难分辨,故障特征的提取和监测点的设置成为臭氧发生器故障诊断的关键。运用电流监测表征电功率变化值,配合温度变化的监测,根据监测点的监测值变化情况判断设备的运行状态,研究了臭氧发生设备的无人在线监测与故障诊断系统。结构简单可行,满足无人状态下监测的实时性和准确性。
英文摘要:
      In am ozone generator, high frequency high voltage power supply and dielectric barrier discharge are used to generate ozone so that there may be more points of fault which are difficult to distinguish. The acquisition of fault feature and setup of monitoring points becomes the key to the fault diagnosis of the ozone generator. The operational status of the equipment is judged according to the variations of monitored values with respect to the electric power and temperature. Non manned online monitoring and fault diagnosis system of the ozone generator is studied. The simple and feasible structure meets the requirement on the non manned real time and accurate monitoring
查看全文  查看/发表评论  下载PDF阅读器
关闭